Butler Winding
Home
Butler Winding, 201 Pillow Street, Butler, PA 16001, 724-283-7230
Request a Quote from Butler Winding
JOB POSTINGS
Custom Transformers - Custom Design
Toroidal Transformers - Custom Built
Bobbin Wound Transformers - Custom Built
Power Transformers - Custom Designed
Common Mode Choke - Custom Designed & Built
Switch Mode Power Transformers - Custom Built
Flyback Transformers - Custom Built
Pulse Transformers - Custom Built
Current Transformers - Custom Built
Surface Mount Transformers - Custom Built
Custom Inductors
Toroidal Inductor - Custom Design
Surface Mount Inductor - Custom Design
Bobbin Wound Inductors - Custom Built
Mag Amp Magnetic Amplifier Custom Built
Transformer Core Types - Custom Built
Custom Winding Capabilities - Custom Design
Resource Library
About Butler Winding
Privacy Policy by Butler Winding
Email Sign Up
Our Blog
     Common Mode Choke Theory for our Custom Built Coils  
 

Common Mode Choke Quote RequestTheory - Common Mode Choke

A common mode choke may be used to reduce a type of electrical noise known as common mode noise.

Electro-magnetic interference (E.M.I.) in the circuit's
environment is one source of electrical noise. E.M.I. induces              Common Mode Choke
or couples unwanted electrical signals into the circuit. It is                        Product Page
desirable to filter out the unwanted noise signals without
significantly affecting the desired signal. Environmental sources        Power Inductors, Chokes 
of E.M.I. often create an independent return path (ground path)                & Reactors FAQs
for the electrical noise signals. The return path of the desired
signal is a different path. Because there are two different return paths, a Common Mode Choke can be used to significantly block (hence reduce) the unwanted noise signal (at the load) without significant reduction in the desired signal.

A.C. Power Lines provide a good example. They are known to carry significant levels of electrical noise. Their long length gives environmental E.M.I. ample opportunity to generate unwanted electrical noise into the power lines.

Figure 2 below illustrates an application without a Common Mode Choke.

Common Mode Choke Fig 2

In the example above, the power line voltage, "Vs", causes current, "Iz", to flow through the load, "Z". At any non-zero instance, Current "Iz" flows into "Z" through one power line wire and returns through the other power line wire. E.M.I. voltage, "Vnc1", causes current "Inc1", to flow through the load "Z". Similarly, E.M.I. voltage, Vnc2 causes current "Inc2" to flow through the load "Z". Because the E.M.I is generating both "Vnc1" and "Vnc2" - the two voltages tend to be in phase. There is very little current flow between them. Current "Inc1" does not flow through both power line wires. It flows through one power line wire and through the ground path. Similarly, current "Inc2" does not flow through both power line wires. It flows through one power line wire and through the ground path. In this example only "Vnc1" produces electrical noise across load "Z" because the "Vnc2" end of "Z" is grounded. In practice, the effective ground point could occur somewhere between the two ends of load "Z".

Figure 3 below illustrates the same application with a Common Mode Choke.

The common mode choke has two windings. Each winding of the common mode choke is inserted between the end of a power line wire and the load.

Common Mode Choke Fig 3


As in Figure 1 below
, current "Iz" flows through both power line wires and currents "Inc1" and "Inc2" each flow through one power line wire and return through the ground path. Observe that current "Iz" flows through both windings but in opposing winding directions, while currents "Inc1" and Inc2" each flow through only one winding and in the same winding direction. The ground path does not flow through a winding.

Common Mode Choke Fig 1

The inductance of Winding A restricts (reduces) the flow of current "Inc1" (when compared to Figure 1), thereby reducing the noise voltage across "Z". Similarly the inductance of winding B restricts (hence reduces) the flow of current "Inc2". Windings A and B have the same number of turns. The ampere-turns created by Current "Iz" (but excluding any "Inc1" current component) flowing through winding A is cancelled by the opposing ampere-turns created by current "Iz" flowing through winding B. Ideally, the cancellation results in zero inductance and no restriction (no reduction) of current "Iz". "Iz" produces the same voltage across load "Z" as it does in Figure 1. In practice this will not be true. The common mode choke will have some leakage flux between windings A and B hence incomplete cancellation. Windings A and B will have some winding resistance. Both of these will have some effect on "Iz" (reduces "Iz").

In contrast, the load current "Iz" flowing through both Winding A and Winding B of the differential choke shown in Figure 1 do not cancel, hence "Iz" will be restricted (reduced). Differential chokes are useful when the electrical noise frequencies are much higher than the operating frequencies. The higher choke impedance at the high frequencies block the electrical noise while having a tolerable effect at the operating frequencies.

Some common mode chokes are intentionally designed to have significant leakage inductance. The leakage inductance acts in series with the load hence the leakage inductance provides differential noise filtering. One common mode choke functions like the combined chokes shown in Figure 1 but may differ in levels.

 

 

 
 
 


 