Completed custom built bobbin wound inductor designed for a 208Vac, 1-phase line reactor – wound with copper foil. The copper foil used is 0.030″ x 3″ wide. This bobbin wound inductor is designed to function as a 208 volt line reactor.
- Inductance: 75uHy
- Frequency: 60Hz
- Hi-Pot Test: 2,000Vac coil to frame
- Core Structure: 1″ x 0.011″ strip wound core
- Dimensions: 5.5″L x 7″H x 3″W
- Termination: 1-1/4″ x 5/8″ x 1/8″ thick tabs with 5/16″ holes
- Mounting Hole Spacing: 5″ x 2.5″ center to center
- Mounting: Chasis mount, 4 x 5/16″ diameter holes
- Finish: Varnish coated (coils only), for field adjustment of gap
- Weight: Approximately 12 pounds
- Part Number: 120-0080